Main Distribution Board
MDB · up to 6300A

Type-tested assemblies to IEC 61439-2, rated for continuous industrial duty. Custom-engineered to project SLD with full form separation and arc-flash containment.

MODEL · SG-MDB-6300 · IEC 61439-2 · 2024
SWITCHGEAR PRO · MDB
Technical Specifications

Engineered for backbone distribution.

Our MDB range is the trunk of a complete LV network — built around copper busbars, cast-resin insulators, and ACB main incomers with full interlocking for source changeover and genset backup.

Standard
IEC 61439-2
Rated voltage (Ue)
690 V AC
Rated insulation voltage (Ui)
1000 V
Rated current (Ie)
up to 6300 A
Rated short-time withstand (Icw)
100 kA / 1s
Rated peak withstand (Ipk)
220 kA
Degree of protection
IP31 · IP41 · IP54 (opt.)
Form of separation
Form 1 · 2b · 3b · 4a · 4b
External colour
RAL 7035 (std) · custom
Configuration

Forms of separation — choose your level.

IEC 61439-2 defines four levels of internal separation. Each form determines how busbars, functional units, and outgoing terminals are segregated — and governs safe operation under live conditions.

FormBusbarFunctional unitsTerminals for external conductorsTypical use
Form 1No separation between any internal componentsSimple distribution, low-duty
Form 2bSeparated from functional unitsUnseparated from each otherWithin the same compartmentStandard commercial buildings
Form 3bSeparated from functional unitsSeparated from each otherIn same compartment as functional unitIndustrial with maintenance needs
Form 4aSeparatedSeparatedSame compartment as associated functional unitMost industrial installations
Form 4bSeparatedSeparatedFully separated own compartmentCritical power · hospitals · data centers
Key Features

Why engineers specify our MDB.

01 / STRUCTURE

Galvanized steel frame

2mm zinc-coated structural members, 1.5mm body panels, bolted assembly for transport in sections up to 4 meters.

02 / BUSBAR

E-Cu electrolytic copper

99.9% pure electrolytic copper busbars, tin-plated at contact surfaces, supported on cast-resin insulators rated 12kV.

03 / BREAKERS

ABB / Schneider / Siemens

Air circuit breakers (ACB) and moulded case (MCCB) from tier-1 European brands, with your choice of manufacturer.

04 / METERING

Multifunction meters

Schneider PM5560 or equivalent, RS485 Modbus output, class 0.5S accuracy for revenue-grade monitoring.

05 / SAFETY

Arc-flash containment

Pressure relief flaps, ventilated roof, interlocked doors with trapped-key systems for safe isolation procedures.

06 / ACCESS

Front-access design

All maintainable components accessible from the front. Back-to-wall installation possible, saving 30% floor space.

Compliance

Built and tested to international standards.

IEC 61439-2
Assembly standard
IEC 60947-2
Circuit breakers
IEC 60529
IP ratings
IEC 61641
Arc-fault guide